
Installing and Upgrading Data
Collectors 6
vCenter Chargeback Manager interacts with the vCenter Server and vCenter Server database through a data
collector. The data collector synchronizes the information in the vCenter Chargeback Manager database
with that in the vCenter Server database.
Other than the data collector that interacts with the vCenter Server database, vCenter Chargeback Manager
provides two more data collectors. These are the vCloud Director data collector and the vShield Manager
data collector. These data collectors enable you to integrate vCloud Director with vCenter Chargeback
Manager.
vCenter Chargeback Manager 2.5.1 supports vCloud Director 1.5.x and vCloud Director 5.1. It also supports
the corresponding versions of vShield Manager.
When you integrate the vCenter Chargeback Manager with vCloud Director 5.1, during the first run of the
vCloud Director data collector jobs, the entire vCloud Director inventory is synchronized in vCenter
Chargeback Manager by call the vCloud Director APIs. After the vCloud Director inventory is
synchronized, the vCloud Director data collector polls the vCloud Director database for chargeback events.
These events details are used to call specific vCenter Chargeback Manager APIs. A chargeback hierarchy for
each org vDC in the vCloud Director setup is created in vCenter Chargeback Manager and also the
corresponding allocation details are set on the entities.
By integrating vCloud Director with vCenter Chargeback Manager, you can perform the following tasks:
n
Meter and charge for allocation and usage of vCloud Director resources, including virtual datacenters,
vApps, templates and media file storage.
n
Meter and charge for external network bandwidth, network count, and network services, such as
DHCP, NAT, and firewall.
n
Deliver multi-tenant chargeback reports.
However, this release does not include support for the following features:
n
Charging for storage utilized by partially created or imported virtual machines, vApps, and templates
and media files.
n
Charging for resources utilized by virtual machines that are created by vShield Edge.
NOTE Only the vCenter Chargeback Manager related events are processed by the vCloud Director data
collector. To update the vCloud Director Org hierarchies in vCenter Chargeback Manager, the
corresponding vCenter Server must be added to vCenter Chargeback Manager and the vCenter Chargeback
Manager data collector must be running to synchronize the vCenter Chargeback Manager database with the
vCenter Server database. If the vCenter Chargeback Manager data collector is not installed or is not running,
then the changes will not be processed and the changes in the vCenter Server and the vCloud Director Org
hierarchy is not accounted for in vCenter Chargeback Manager.
VMware, Inc.
45
Comentarios a estos manuales